Ritchie Bros. Auctioneers logo
التمويلالمواقع
  • General Appearance with Picture, Left Front Corner
  • General Appearance with Picture, Left Rear Corner
  • General Appearance with Picture, Right Rear Corner
  • General Appearance with Picture, Right Front Corner

91 من الصور

العنصر 14555464

2017 Prinoth Panther T16 76.5 ft رافعات تحميل جوية w/2016 Altec A77T

الموقع

Beulah, ND

Beulah, ND

الاستخدام

2,391 ساعات

2,391 ساعات

الرقم التسلسلي

935410016

935410016

Loading...

معلومات تفصيلية حول المعدات

هذه المجموعة محمية بموجب IronClad Assurance

اشترِ بثقة عندما تعرف أنَّ هذه المجموعة قد فُحصت تفصيليًا وبالكامل بواسطة فاحِص مؤهل.

رقم الهوية

#14555464


ياردة

كلا


الميزات

Enclosed Cab, Air Conditioner, Tier 4, 2015 US EPA Label, Cat C7.1 6 Cylinder 205 kW 7.01 L Diesel Engine, Requires Diesel Exhaust Fluid, 800 lb Capacity, Rear Mounted, Two-Person Articulating-Telescopic Boom, Flatbed, Material Handling Jib, A-Outriggers, Rear Outriggers, Bumper Mounted Winch, 40 in Rubber Tracks, 33,500 lb Payload Capacity, Max Speed of 8 mph, c/w Altec Model A77-T Aerial Device s/n 0516CT2183, 77 ft Platform Height, Non Over-Center Aerial Device, 46.5 ft Platform Height, Automatic Upper Boom Stow, Closed Center Hydraulic System, Continuous Rotation, Telescopic Upper Boom, Material Handling Jib

General Appearance
General Appearance with Picture, Left Front Corner
General Appearance with Picture, Left Rear Corner
General Appearance with Picture, Right Rear Corner
General Appearance with Picture, Right Front Corner
General Appearance with Serial Number / VIN
General Appearance with Hour Meter / Odometer
General Appearance with Paint
General Appearance with Sheet Metal (fiberglass) Condition
General Appearance with Steps/Ladders
General Appearance with Glass
General Appearance with Exterior Lights
General Appearance with
General Appearance with
General Appearance with
General Appearance with
General Appearance with
General Appearance with

Serial Number / VIN

935410016


Hour Meter / Odometer

2391 hrs-No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.


Paint


Sheet Metal (fiberglass) Condition


Steps/Ladders


Glass


Exterior Lights

Operational

Safety
Safety with Safety Lock Out/Stop
Safety with

Travel Alarm

Operational


Horn

Operational


Seat Belts

Operational


Safety Lock Out/Stop

Operational


Current Safety Manual


Current Operator/Maintenance Manual

Control Station
Control Station with Seats/Armrests
Control Station with Mirrors
Control Station with Steering Controls
Control Station with Hydraulic Controls
Control Station with Drivetrain Controls
Control Station with Dash Console
Control Station with Engine Oil Pressure
Control Station with Warning Lights
Control Station with Gauges
Control Station with Limited Function Check
Control Station with
Control Station with
Control Station with

Seats/Armrests


Mirrors


Steering Controls


Hydraulic Controls


Drivetrain Controls


Dash Console


Engine Oil Pressure

The fault indicator shuts off after the engine oil pressure rises.


Warning Lights

Operational


Gauges

Operational


Air Conditioner

The ambient temperature is too cold to check


Heater

Operational


Limited Function Check

The main components are in place and operational as noted. Had to use a jumper wire on starter relay to get engine to start.

Engine
Engine with Emission Label
Engine with A/C Compressor
Engine with Blow-by (subjective visual observation)
Engine with Exhaust System
Engine with Radiator
Engine with Oil Leaks
Engine with Fuel Leaks
Engine with Cooling System Leaks
Engine with Engine - Left Side
Engine with Engine - Right Side
Engine with DEF / AdBlue Tank
Engine with Limited Function Check
Engine with

Emission Label


A/C Compressor

In place; ambient temperature too cold to check operation


Blow-by (subjective visual observation)

Minor


Starter

Intermittent engagement, Had to use a jumper wire on starter relay to get engine to start.


Exhaust System


Radiator


Oil Leaks

No dripping leaks


Fuel Leaks

No dripping leaks


Cooling System Leaks

No dripping leaks


Engine - Left Side


Engine - Right Side


DEF / AdBlue Tank


Limited Function Check

The engine started and ran.

Drivetrain
Drivetrain with Drive Motors
Drivetrain with Final Drives
Drivetrain with
Drivetrain with

Drive Motors


Final Drives


Limited Function Check (Drivetrain-Track)

The drivetrain was operational without a load.

Hydraulics
Hydraulics with Pumps (Hydraulics)
Hydraulics with Hydraulic Motors
Hydraulics with Valves
Hydraulics with Hydraulic Tank
Hydraulics with Hoses
Hydraulics with Auxiliary Hydraulic Plumbing
Hydraulics with Cylinder(s)
Hydraulics with Cylinder Pins and Bushings
Hydraulics with
Hydraulics with
Hydraulics with
Hydraulics with
Hydraulics with
Hydraulics with
Hydraulics with

Pumps (Hydraulics)


Hydraulic Motors


Valves


Hydraulic Tank


Hoses


Auxiliary Hydraulic Plumbing

Not operationally checked


Cylinder(s)


Cylinder Pins and Bushings


Limited Function Check

The hydraulic system was operational.

Configuration
Configuration with
Configuration with
Configuration with
Configuration with
Configuration with
Configuration with
Configuration with
Configuration with
Configuration with
Configuration with
Configuration with
Configuration with
Configuration with
Undercarriage
Undercarriage with Left Roller Frame
Undercarriage with Left Track Tensioner
Undercarriage with
Undercarriage with
Undercarriage with Left Carrier Rollers
Undercarriage with Left Idler
Undercarriage with Left Sprocket
Undercarriage with Right Roller Frame
Undercarriage with Right Track Tensioner
Undercarriage with
Undercarriage with
Undercarriage with Right Carrier Rollers
Undercarriage with Right Idler
Undercarriage with Right Sprocket

Left Roller Frame


Left Track Tensioner


Left Carrier Rollers


Left Idler


Left Sprocket


Right Roller Frame


Right Track Tensioner


Right Carrier Rollers


Right Idler


Right Sprocket

Oil Sample Analysis

Oil Sample Analysis

engine
date of analysisJan 22, 2026
Silicon6.27 PPM
Tin0.97 PPM
Silver0 PPM
Aluminum10.76 PPM
Chromium2.61 PPM
Lead0 PPM
Copper8.26 PPM
Nickel1.33 PPM
Iron70.93 PPM
GlycolNEG
WaterNEG
Fuel<5%

معلومات إضافية
بنود المزايدة والبيع
لا يمكن سحب المزايدات. كل شيء يُباع "كما هو، أينما هو". اقرأ الشروط والبنود كاملةً قبل تقديم المزايدات.
بنود المزايدة والبيع
رسوم المعاملات
يتعيّن على المشترين الناجحين دفع رسوم معاملة خاصة بالمشتري.
تفاصيل إضافية
الدفع

يجب دفع المبلغ الكامل للعناصر بحلول ‎الأربعاء، 8 يناير 3000‎. ستُطبق رسوم تأخير بعد تاريخ الاستحقاق.

المدفوعات
الشحن والاستلام
  • لا يمكن للمشترين نقل مشترياتهم من موقع المزاد حتى يدفعوا فاتورتهم كاملةً.
  • يجب على السائقين إحضار نسخة من تذكرة الإفراج عن العنصر من شركة ريتشي وإخوانه لاستلامه.
  • لقد عقدنا شراكة مع مزودي خدمات شحن موثوق بهم لنُسهِّل عليك العثور على أفضل شركات النقل بأقل الأسعار. اطلب عروض أسعار مجانية أو احصل على تقديرات فورية لتكلفة الشحن من المواقع الإلكترونية لمزودي الخدمات لدينا.
RB Logistics
الحصول على عرض أسعار

انقل معداتك حيث يجب أن تكون مع حلول الشحن واللوجستيات المتكاملة من الباب إلى الباب من ريتشي وإخوانه. نهتم بكل خطوة في الرحلة من خلال خدمتنا الشاملة لعبور معداتك للحدود والقارات والمحيطات بسرعة وكفاءة

معلومات عامة

المعلومات التفصيلية حول المعدات محدودة النطاق، ولم تفحص شركة ريتشي وإخوانه للمزادات العلنية أي جوانب أو مكونات من المعدات بخلاف تلك المنصوص عليها صراحة في هذه الوثيقة. ما لم يُنص صراحة على ذلك، نحن لا نقدم أي تعهدات أو ضمانات، صريحة أو ضمنية، في ما يتعلق بالمعدات أو مكوناتها، بما في ذلك على سبيل المثال لا الحصر أي تعهدات أو ضمانات تتعلق بالتشغيل أو المطابقة أو الامتثال لأي معيار أمان أو متطلبات أي سلطة أو هيئة تنظيمية معنية، أو الملاءمة لأي غرض معين، أو قابلية التسويق. ننصحك بشدة بإجراء فحص تفصيلي خاص بك للمعدات قبل تقديم المزايدات.

التشغيل

لم تُختبر المعدات تحت حمل ولم تُشغَّل على جميع السرعات المتاحة. نحن لا نقدم أي تعهد أو ضمان بأن المعدات تعمل وفق مواصفات الشركات المصنعة. لم يُجرَ أي فحص في ما يتعلق بأي جانب تشغيلي بخلاف تلك الجوانب المدرجة صراحة في هذه الوثيقة. تم توفير صور مختارة لبعض مكونات الهيكل السفلي الفردية، وقد لا تعكس هذه الصور حالة الهيكل السفلي بأكمله.

الأبعاد

القياسات مُقدمة بشكل تقريبي فقط. قد تختلف الأبعاد الفعلية للحمولة بناءً على ارتفاع الشاحنة/المقطورة وتكوين/وضع الآلة المُحمَّلة. تقع على عاتق المشتري مسؤولية قياس جميع الأحمال قبل مغادرة موقع المزاد الخاص بنا لضمان أن الحمولة آمنة للنقل. يجب أن يتحقق المشتري من جميع القياسات. لا تعتمد على هذه القياسات لأغراض النقل.

  • حول شركة ريتشي وإخوانه
  • حوكمة الشركات
  • المستثمرون
  • الوظائف
  • المدوّنة
  • مركز الأمان
بيان الخصوصيةالسياسات القانونيةعدم بيع معلوماتي الشخصية
© 1999-2026 Ritchie Bros. Auctioneers, Inc. كل الحقوق محفوظة. علامات تجارية متعددة ملك لأصحابها المعنيين