204 من الصور
الموقع
Curtis Bay, MD
Curtis Bay, MD
الاستخدام
58,029 mi
58,029 mi
الرقم التسلسلي
5KKHAXFE1LLME0060
5KKHAXFE1LLME0060
Loading...
هذه المجموعة محمية بموجب IronClad Assurance
اشترِ بثقة عندما تعرف أنَّ هذه المجموعة قد فُحصت تفصيليًا وبالكامل بواسطة فاحِص مؤهل.
رقم الهوية
#14914691
ياردة
كلا
الميزات
Cummins 6 Cylinder Diesel Engine, 2019 US EPA Label, Requires Diesel Exhaust Fluid, Air Conditioner, Cruise Control, Power Windows, Engine Brake, Allison Automatic Transmission, Differential Lock, 20000 lb Front Axle, 46000 lb Rears, 66000 lb GVWR, Air Ride Cab, 315/80R22.5 Front Tires, 11R22.5 Rear Tires, Dual Steering Boxes, Double Frame, Spring Suspension, 282 in Wheelbase, PTO, Wet Kit, Steel Debris Tank, Vibrator, Fresh Water Tank, Hydraulic Lift Tailgate, Wash Down System, Hydraulic Tailgate Locks, Telescopic Boom, 8 in Suction Hose, Cat Pumps PTO Driven Pump, Howden 824 RCS-V18 HG Black W/O Shroud Blower w/ 1647.1 hrs, 49785 Boiler w/ 277 hrs, Cord and Cordless Remote Controls, Rearview Camera
ملحوظات
<br><br>**Title may not be available for up to 60 business days after auction.**



























Serial Number / VIN
5KKHAXFE1LLME0060
Second Serial Number/VIN Photo
Hour Meter / Odometer
58029 mi-No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Motor Vehicle Safety Standards Label
Yes
Paint
Sheet Metal (fiberglass) Condition
Steps/Ladders
Passenger side step not mounted properly, Bolt missing
Hand Rails
Glass
Exterior Lights
Operational
Steer Axle
Rear Axle
Rear Axle



































Emissions Information
2019 US EPA Label, Requires Diesel Exhaust Fluid
Emission Label
A/C Compressor
Operational
Blow-by (subjective visual observation)
Significant
Starter
Operational
Air Compressor
Operational
Fuel System
Operational
Exhaust System
Diesel Particulate Filter
Radiator
Oil Leaks
Rear of engine, Oil Pan
Fuel Leaks
No dripping leaks
Cooling System Leaks
No dripping leaks
Engine - Left Side
Engine - Right Side
DEF / AdBlue Tank
Limited Function Check
The engine started and ran.































Engine Hours
Steering switch not working to get engine hours
Mirrors
Window Controls
Both Power
Seats/armrests
Seat Belts
Operational
Steering Control
Steering wheel switches inoperable
Horn
Air horn operational, Electric horn operational
Oil Pressure
The gauge registers in the operating range.
Warning Lights
Operational
Gauges
Operational
Gear Selector
Brake Control
Operational
Engine Brake
Not operationally checked
PTO Control
Operational
ECM Miles
58029.3 ECM mi
Air Conditioner
Operational
Heater
Operational
Limited Function Check
The main components are in place and operational as noted.


















































Steering Components
Steer Axle
Dripping leak
Transmission
Operational
Power Take Off
Operational
PTO Pump
Operational
Frame Condition
Front Drive Axle
Rear Drive Axle
Limited Function Check
The drivetrain was operational without a load.
Cab Suspension Air Bags
Suspension Springs/Hangers
Suspension Bushings
Left Steer Tire
Left Front Drive Tires
Left Rear Drive Tires
Right Rear Drive Tires
Right Front Drive Tires
Right Steer Tire
Wheel Condition
Wheel Studs
Wet Kit Plumbing
Hydraulic Tank
Limited Function Check - Brakes
The service brakes are operational, The park brake is operational.





























































Vacuum Intake Hose
Vacuum Pump
Vacuum Drive
PTO Driven
Pre Filter
Debris Tank
High Lift Dump Option, Hydraulic Door Locks
Water Tank
Not operationally checked
Boom Condition
Pressure Pump - Water
PTO Powered
Wash Down System
Remote Control
Operational
Tool/Storage Boxes
Limited Function Check
The main chassis components functioned when checked without a load.
Oil Sample Analysis
| engine | |
|---|---|
| date of analysis | Mar 31, 2026 |
| Silicon | 5.82 PPM |
| Tin | 0.13 PPM |
| Silver | 0.11 PPM |
| Aluminum | 10.18 PPM |
| Chromium | 5.89 PPM |
| Lead | 2.12 PPM |
| Copper | 7.46 PPM |
| Nickel | 1.46 PPM |
| Iron | 96.19 PPM |
| Glycol | NEG |
| Water | NEG |
| Fuel | <5% |
يجب دفع المبلغ الكامل للعناصر بحلول الأربعاء، 8 يناير 2031. ستُطبق رسوم تأخير بعد تاريخ الاستحقاق.
انقل معداتك حيث يجب أن تكون مع حلول الشحن واللوجستيات المتكاملة من الباب إلى الباب من ريتشي وإخوانه. نهتم بكل خطوة في الرحلة من خلال خدمتنا الشاملة لعبور معداتك للحدود والقارات والمحيطات بسرعة وكفاءة
المعلومات التفصيلية حول المعدات محدودة النطاق، ولم تفحص شركة ريتشي وإخوانه للمزادات العلنية أي جوانب أو مكونات من المعدات بخلاف تلك المنصوص عليها صراحة في هذه الوثيقة. ما لم يُنص صراحة على ذلك، نحن لا نقدم أي تعهدات أو ضمانات، صريحة أو ضمنية، في ما يتعلق بالمعدات أو مكوناتها، بما في ذلك على سبيل المثال لا الحصر أي تعهدات أو ضمانات تتعلق بالتشغيل أو المطابقة أو الامتثال لأي معيار أمان أو متطلبات أي سلطة أو هيئة تنظيمية معنية، أو الملاءمة لأي غرض معين، أو قابلية التسويق. ننصحك بشدة بإجراء فحص تفصيلي خاص بك للمعدات قبل تقديم المزايدات.
لم تُختبر المعدات تحت حمل ولم تُشغَّل على جميع السرعات المتاحة. نحن لا نقدم أي تعهد أو ضمان بأن المعدات تعمل وفق مواصفات الشركات المصنعة. لم يُجرَ أي فحص في ما يتعلق بأي جانب تشغيلي بخلاف تلك الجوانب المدرجة صراحة في هذه الوثيقة. تم توفير صور مختارة لبعض مكونات الهيكل السفلي الفردية، وقد لا تعكس هذه الصور حالة الهيكل السفلي بأكمله.
القياسات مُقدمة بشكل تقريبي فقط. قد تختلف الأبعاد الفعلية للحمولة بناءً على ارتفاع الشاحنة/المقطورة وتكوين/وضع الآلة المُحمَّلة. تقع على عاتق المشتري مسؤولية قياس جميع الأحمال قبل مغادرة موقع المزاد الخاص بنا لضمان أن الحمولة آمنة للنقل. يجب أن يتحقق المشتري من جميع القياسات. لا تعتمد على هذه القياسات لأغراض النقل.