الميزات
Enclosed Cab, Air Conditioner, Rear View Camera, Air Ride Seat, Ride Control, Autoshift, Joystick Steering, Traction Control, 2020 US EPA Label, CARB Compliant, Requires Diesel Exhaust Fluid, Auto Lube, 9.8 cyd 144 in Bucket




















Serial Number / VIN
1DW844LAALF707729
Body Panels
Right side cover damaged, Left battery box damaged, Right battery box damaged, Right side engine compartment hinges damaged.
Paint
Limestone residue, Damage
Fenders
Left front missing, Left rear missing, Right front missing, Right rear missing
Hand Rails
Right front hand rails bent
Exterior Lights
All lights operational
Steps
Left cab steps bent, Right cab steps bent


Travel Alarm
Operational
Horn
Operational
Seat Belts
Operational
Safety Lock Out/Stop
Operational
Current Safety Manual
Current Operator/Maintenance Manual




















Seat/Armrests
No visible damage or missing components
Glass
No visible damage or missing components
Mirrors
Cab Doors
No visible damage or missing components
Steering Controls
Hydraulic Controls
Drivetrain Controls
Dash Console
Engine Oil Pressure
The gauge registers in the operating range.
Warning Lights
Operational, Tire Monitor, Warning light stays on
Gauges
Operational
Rear View Camera
Camera inoperable
Hour Meter / Odometer
19994 hrs-No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Air Conditioner
The ambient temperature is too cold to check
Heater
Operational
Limited Function Check
The main components are in place and operational as noted.










Engine
2020 US EPA Label, CARB Compliant, Requires Diesel Exhaust Fluid
Emission Label
A/C Compressor
In place; ambient temperature too cold to check operation
Blow-by (subjective visual observation)
Visible
Starter
Operational
Exhaust System
No visible damage or missing components
Radiator
Oil Leaks
No dripping leaks
Fuel Leaks
No dripping leaks
Cooling System Leaks
No dripping leaks
Engine - Left Side
Engine - Right Side
DEF / AdBlue Tank
Limited Function Check
The engine started and ran. Item was running prior to arrival for inspection.















Transmission
Operational, Dripping leak
Transfer Case / Drop Box
Operational, Dripping leak
Front Drive Axle
Rear Drive Axle
Final Drives
Limited Function Check
The drivetrain was operational.














Pumps (Hydraulics)
Dripping leak
Valves
Hydraulic Tank
Hoses (Hydraulics)
Leaks
Loader Lift Cylinders
Movement
Bucket Tilt Cylinders
Heavy pin and bushing movement
Steering Cylinders
Heavy pin and bushing movement
Limited Function Check
The hydraulic system was operational.








































Articulating Center Pins
Movement
Brake Type
Hydraulic
Master Cylinder
Brake Lines/Hoses
Park Brake
Limited Function Check - Brakes
The brake system functioned, stopping and holding the machine.
Frame Condition
Left Front Tire
Bridgestone V-Steel Traction Stability 875/65R29 43 /32" Tread Depth
Left Rear Tire
Bridgestone V-Steel Traction Stability 875/65R29 40 /32" Tread Depth Low air pressure
Right Rear Tire
Bridgestone V-Steel Traction Stability 875/65R29 42 /32" Tread Depth
Right Front Tire
Bridgestone V-Steel Traction Stability 875/65R29 43 /32" Tread Depth
Wheel Condition
No visible damage or missing components
Lift Arm Condition
Chassis to Arm Pins
Heavy movement
Tilt Linkage
Tilt Linkage Pins and Bushings
Heavy movement
Bucket to Arm Pins
Heavy movement
Limited Function Check
The main components were operational except as noted.













Loader Bucket Condition
Loader Bucket Cutting Edge
Edge worn
يجب دفع المبلغ الكامل للعناصر بحلول الأربعاء، 8 يناير 3000. ستُطبق رسوم تأخير بعد تاريخ الاستحقاق.
انقل معداتك حيث يجب أن تكون مع حلول الشحن واللوجستيات المتكاملة من الباب إلى الباب من ريتشي وإخوانه. نهتم بكل خطوة في الرحلة من خلال خدمتنا الشاملة لعبور معداتك للحدود والقارات والمحيطات بسرعة وكفاءة
المعلومات التفصيلية حول المعدات محدودة النطاق، ولم تفحص شركة ريتشي وإخوانه للمزادات العلنية أي جوانب أو مكونات من المعدات بخلاف تلك المنصوص عليها صراحة في هذه الوثيقة. ما لم يُنص صراحة على ذلك، نحن لا نقدم أي تعهدات أو ضمانات، صريحة أو ضمنية، في ما يتعلق بالمعدات أو مكوناتها، بما في ذلك على سبيل المثال لا الحصر أي تعهدات أو ضمانات تتعلق بالتشغيل أو المطابقة أو الامتثال لأي معيار أمان أو متطلبات أي سلطة أو هيئة تنظيمية معنية، أو الملاءمة لأي غرض معين، أو قابلية التسويق. ننصحك بشدة بإجراء فحص تفصيلي خاص بك للمعدات قبل تقديم المزايدات.
لم تُختبر المعدات تحت حمل ولم تُشغَّل على جميع السرعات المتاحة. نحن لا نقدم أي تعهد أو ضمان بأن المعدات تعمل وفق مواصفات الشركات المصنعة. لم يُجرَ أي فحص في ما يتعلق بأي جانب تشغيلي بخلاف تلك الجوانب المدرجة صراحة في هذه الوثيقة. تم توفير صور مختارة لبعض مكونات الهيكل السفلي الفردية، وقد لا تعكس هذه الصور حالة الهيكل السفلي بأكمله.
القياسات مُقدمة بشكل تقريبي فقط. قد تختلف الأبعاد الفعلية للحمولة بناءً على ارتفاع الشاحنة/المقطورة وتكوين/وضع الآلة المُحمَّلة. تقع على عاتق المشتري مسؤولية قياس جميع الأحمال قبل مغادرة موقع المزاد الخاص بنا لضمان أن الحمولة آمنة للنقل. يجب أن يتحقق المشتري من جميع القياسات. لا تعتمد على هذه القياسات لأغراض النقل.