




85 من الصور
الموقع
Bowling green, KY
Bowling green, KY
الرقم التسلسلي
ZF1P101D1C9001077
ZF1P101D1C9001077
Loading...
هذه المجموعة محمية بموجب IronClad Assurance
اشترِ بثقة عندما تعرف أنَّ هذه المجموعة قد فُحصت تفصيليًا وبالكامل بواسطة فاحِص مؤهل.
رقم الهوية
#14707354
ياردة
كلا
السنة
2019
المصنّع
نوع الأصل
الرقم التسلسلي أو رقم تعريف المركبة
ZF1P101D1C9001077
الميزات
Enclosed Cab, Air Conditioner, Rear View Camera, 56 ft Max Lift Height, 11000 lb Max Lift Capacity, Tier 4, Requires Diesel Exhaust Fluid, 54 in Forks, Hydraulic Coupler, Frame Leveling, Auxiliary Hydraulic Plumbing
ملحوظات
Comes with ironclad assurance. Subject to Kentucky sales tax















Picture, Left Front Corner
Picture, Left Rear Corner
Picture, Right Rear Corner
Picture, Right Front Corner
Serial Number / VIN
ZF1P101D1C9001077
CE Mark
No CE mark found
Hour Meter / Odometer
SEE REPORT 511 Hours; The age and condition of the indicates more hours than shown on the hours meter.-No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Paint
Sheet Metal (fiberglass) Condition
Steps/Ladders
Hand Rails
Glass
The door glass is broken out.
Exterior Lights
Operational



Travel Alarm
Operational
Horn
Inoperable
Seat Belts
Operational
Safety Lock Out/Stop
Operational
Current Safety Manual
Current Operator/Maintenance Manual












Mirrors
Seats/Armrests
Hydraulic Controls
No response when unlocked and activated, shows error code and sounds alarm
Steering Control
Drivetrain Controls
Transmission Disconnect Control
Load Charts
Chart book in cab
Engine Oil Pressure
The fault indicator shuts off after the engine oil pressure rises.
Warning Lights
Operational
Gauges
Operational
Air Conditioner
The ambient temperature is too cold to check
Heater
Operational
Limited Function Check
The main components are in place and operational as noted. The rear-view camera is not operational. The hydraulic error light stays on.














Engine
US EPA Label not legible Requires Diesel Exhaust Fluid
Emission Label
Illegible
A/C Compressor
In place; ambient temperature too cold to check operation
Blow-by (subjective visual observation)
Minor
Starter
Operational
Exhaust System
Radiator
Oil Leaks
No dripping leaks
Fuel Leaks
No dripping leaks
Cooling System Leaks
No dripping leaks
Engine - Left Side
Engine - Right Side
DEF / AdBlue Tank
Limited Function Check
After jump starting, the engine ran. The engine would not re-start after shutting down without jump starting.









Transmission
Operational
Transfer Case / Drop Box
Operational
Front Drive Axle
Front Axle Oscillating Pin
Rear Drive Axle
Rear Axle Oscillating Pin
Final Drives
Limited Function Check
The drivetrain was operational.











Pumps (Hydraulics)
Valves
Hydraulic Tank
Hoses (Hydraulics)
Auxiliary Hydraulic Plumbing
Not operationally checked, Front
Boom Lift Cylinder(s)
Telescopic Boom Cylinders
Carriage Tilt Cylinder
Frame Leveling Cylinders
Steering Cylinders
Limited Function Check
The hydraulic system is operational except all boom, auxiliary hydraulic and frame leveling functions are inoperable.

















Boom Condition
Left Side of Boom
Right Side of Boom
Chain / Tensioners
Rollers and Guides
Boom Wear Guides
Steering Linkage
Frame Condition
Limited Function Check
The main chassis components functioned during a limited check.
Master Cylinder
Brake Control
Brake Lines/Hoses
Park Brake
Stopped from a slow roll
Limited Function Check - Brakes
The service brakes are operational, The park brake is operational.
Tire Brands
Mitas
Left Front Tire
Left Rear Tire
Right Rear Tire
Right Front Tire
Wheel Condition
Wheel Studs, Nuts, Lugs




Loader Quick Coupler
Not operationally checked
Load Back Rest
Forks
Oil Sample Analysis
| engine | |
|---|---|
| date of analysis | Nov 12, 2025 |
| Silicon | 15.1 PPM |
| Tin | 2.53 PPM |
| Silver | 0 PPM |
| Aluminum | 1.62 PPM |
| Chromium | 0.32 PPM |
| Lead | 0.95 PPM |
| Copper | 13.77 PPM |
| Nickel | 0.4 PPM |
| Iron | 12.39 PPM |
| Glycol | NEG |
| Water | NEG |
| Fuel | <5% |
يجب دفع المبلغ الكامل للعناصر بحلول السبت، 28 فبراير 2026. ستُطبق رسوم تأخير بعد تاريخ الاستحقاق.
المدفوعاتالمعلومات التفصيلية حول المعدات محدودة النطاق، ولم تفحص شركة ريتشي وإخوانه للمزادات العلنية أي جوانب أو مكونات من المعدات بخلاف تلك المنصوص عليها صراحة في هذه الوثيقة. ما لم يُنص صراحة على ذلك، نحن لا نقدم أي تعهدات أو ضمانات، صريحة أو ضمنية، في ما يتعلق بالمعدات أو مكوناتها، بما في ذلك على سبيل المثال لا الحصر أي تعهدات أو ضمانات تتعلق بالتشغيل أو المطابقة أو الامتثال لأي معيار أمان أو متطلبات أي سلطة أو هيئة تنظيمية معنية، أو الملاءمة لأي غرض معين، أو قابلية التسويق. ننصحك بشدة بإجراء فحص تفصيلي خاص بك للمعدات قبل تقديم المزايدات.
لم تُختبر المعدات تحت حمل ولم تُشغَّل على جميع السرعات المتاحة. نحن لا نقدم أي تعهد أو ضمان بأن المعدات تعمل وفق مواصفات الشركات المصنعة. لم يُجرَ أي فحص في ما يتعلق بأي جانب تشغيلي بخلاف تلك الجوانب المدرجة صراحة في هذه الوثيقة. تم توفير صور مختارة لبعض مكونات الهيكل السفلي الفردية، وقد لا تعكس هذه الصور حالة الهيكل السفلي بأكمله.
القياسات مُقدمة بشكل تقريبي فقط. قد تختلف الأبعاد الفعلية للحمولة بناءً على ارتفاع الشاحنة/المقطورة وتكوين/وضع الآلة المُحمَّلة. تقع على عاتق المشتري مسؤولية قياس جميع الأحمال قبل مغادرة موقع المزاد الخاص بنا لضمان أن الحمولة آمنة للنقل. يجب أن يتحقق المشتري من جميع القياسات. لا تعتمد على هذه القياسات لأغراض النقل.