132 من الصور
الموقع
Newnan, GA
Newnan, GA
الاستخدام
267,437 mi
267,437 mi
الرقم التسلسلي
1M2K197C97M037279
1M2K197C97M037279
Loading...
هذه المجموعة محمية بموجب IronClad Assurance
اشترِ بثقة عندما تعرف أنَّ هذه المجموعة قد فُحصت تفصيليًا وبالكامل بواسطة فاحِص مؤهل.
رقم الهوية
#15768619
ياردة
نعم
الميزات
Mack 6 Cylinder Diesel Engine, 22121.8 Engine hrs, Air Conditioner, Cruise Control, Engine Brake, Mack T310 10-Speed Manual Transmission, Aluminum Wheels, 425/65R22.5 Front Tires, 11R22.5 Rear Tires, Steerable Air Lift Pusher Axle, Camelback Spring Suspension, 272 in Wheelbase, PTO, 5643 Pump Hours, Radio and Cable Remote Controls, Outrigger Pads, Auto Lube, EBC (Ergonic Boom Control)















Serial Number / VIN
1M2K197C97M037279
Frame Stamp Serial Number/VIN Photo
Hour Meter / Odometer
267437 mi-No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Motor Vehicle Safety Standards Label
No
Paint
Sheet Metal (fiberglass) Condition
Steps/Ladders
Hand Rails
Glass
Exterior Lights
Operational
Steer Axle
Rear Axle
Rear Axle
Rear Axle

















Emissions Information
No US EPA Label Present
A/C Compressor
Compressor will not engage
Blow-by (subjective visual observation)
Significant
Starter
Operational
Air Compressor
Operational
Fuel System
Operational
Exhaust System
Radiator
Oil Leaks
Side of engine, Oil Pan, Extensive engine oil overspray and film coating the entirety of the undercarriage and chassis components
Fuel Leaks
No dripping leaks
Cooling System Leaks
No dripping leaks
Engine - Left Side
Engine - Right Side
Limited Function Check
The engine started and ran.


















Engine Hours
22121.8 Engine hrs
Mirrors
Window Controls
Both Manual
Seats/armrests
Seat Belts
Operational
Steering Control
Horn
Air horn operational, Electric horn operational
Oil Pressure
The gauge registers in the operating range.
Warning Lights
Operational
Gauges
Operational
Gear Selector
Brake Control
Operational
Engine Brake
Not operationally checked
Clutch
Engages
PTO Control
Operational
Air Conditioner
Fan blower functions but not blowing cool air
Heater
Operational
Limited Function Check
The main components are in place and operational as noted. Interior driver door damaged






























Transmission
Operational, Dripping leak
PTO Pump
Operational
Steer Axle
Front Drive Axle
Rear Drive Axle
Axle Bump Stops
In place
Limited Function Check - Carrier
The drivetrain was operational without a load.
Steering Linkage
Steering Wheel Play
Brake Type
Air
Master Cylinder/Brake Control
Brake Lines/Hoses
Park Brake
Held against power
Limited Function Check - Brakes
The brake system functioned, stopping and holding the machine.
Springs/Hangers Condition
Frame Condition
Cross Members
Automatic Lube System
Yes
Tire Condition
Wheel Condition
Wheel Studs

















Pumps (Hydraulics)
Buildup
Hydraulic Motors
Valves
Hydraulic Tank
Hoses (Hydraulic)
Swing Motor
Boom Cylinders
Pump Cylinders
Lift Cylinders
Limited Function Check
Hydraulic system was operational during a limited function test. Unit was not fully set up to test all hydraulic functions.










Pump Unit Serial Number
170207601
Pump Cell:
38Z
Pump Hours
5643 Pump Hours
Main Boom - Conveyor
38 m, 34 m
Wear Pads
Raise / Lower Mechanism
Hydraulic raise
Support Frame
Turntable Bearing
Remote Control
Not operationally checked

























Outrigger Condition
Remote Control
Not operationally checked
Boom Condition
Boom Pipe
Receiver/Hopper
S Valve Wear Parts
Agitator
Concrete Pump Cylinders
Turntable Bearing
Water Tank
Not operationally checked
Water Pump
Not operationally checked
Rear Body Steps
Body Decks and Sideboards
Oil Sample Analysis
| engine | |
|---|---|
| date of analysis | Sep 10, 2026 |
| Silicon | 10 PPM |
| Tin | 0.14 PPM |
| Silver | 0.03 PPM |
| Aluminum | 1.33 PPM |
| Chromium | 0.03 PPM |
| Lead | 3.71 PPM |
| Copper | 1.05 PPM |
| Nickel | 0.26 PPM |
| Iron | 10.65 PPM |
| Glycol | NEG |
| Water | NEG |
| Fuel | <5% |
يجب دفع المبلغ الكامل للعناصر بحلول الأربعاء، 8 يناير 3000. ستُطبق رسوم تأخير بعد تاريخ الاستحقاق.
انقل معداتك حيث يجب أن تكون مع حلول الشحن واللوجستيات المتكاملة من الباب إلى الباب من ريتشي وإخوانه. نهتم بكل خطوة في الرحلة من خلال خدمتنا الشاملة لعبور معداتك للحدود والقارات والمحيطات بسرعة وكفاءة
المعلومات التفصيلية حول المعدات محدودة النطاق، ولم تفحص شركة ريتشي وإخوانه للمزادات العلنية أي جوانب أو مكونات من المعدات بخلاف تلك المنصوص عليها صراحة في هذه الوثيقة. ما لم يُنص صراحة على ذلك، نحن لا نقدم أي تعهدات أو ضمانات، صريحة أو ضمنية، في ما يتعلق بالمعدات أو مكوناتها، بما في ذلك على سبيل المثال لا الحصر أي تعهدات أو ضمانات تتعلق بالتشغيل أو المطابقة أو الامتثال لأي معيار أمان أو متطلبات أي سلطة أو هيئة تنظيمية معنية، أو الملاءمة لأي غرض معين، أو قابلية التسويق. ننصحك بشدة بإجراء فحص تفصيلي خاص بك للمعدات قبل تقديم المزايدات.
لم تُختبر المعدات تحت حمل ولم تُشغَّل على جميع السرعات المتاحة. نحن لا نقدم أي تعهد أو ضمان بأن المعدات تعمل وفق مواصفات الشركات المصنعة. لم يُجرَ أي فحص في ما يتعلق بأي جانب تشغيلي بخلاف تلك الجوانب المدرجة صراحة في هذه الوثيقة. تم توفير صور مختارة لبعض مكونات الهيكل السفلي الفردية، وقد لا تعكس هذه الصور حالة الهيكل السفلي بأكمله.
القياسات مُقدمة بشكل تقريبي فقط. قد تختلف الأبعاد الفعلية للحمولة بناءً على ارتفاع الشاحنة/المقطورة وتكوين/وضع الآلة المُحمَّلة. تقع على عاتق المشتري مسؤولية قياس جميع الأحمال قبل مغادرة موقع المزاد الخاص بنا لضمان أن الحمولة آمنة للنقل. يجب أن يتحقق المشتري من جميع القياسات. لا تعتمد على هذه القياسات لأغراض النقل.