165 Photos
Longview, TX
167,773 mi (270,005 km)
225919
Loading...
هذه المجموعة محمية بموجب IronClad Assurance
اشترِ بثقة عندما تعرف أنَّ هذه المجموعة قد فُحصت تفصيليًا وبالكامل بواسطة فاحِص مؤهل.
رقم الهوية
#14040513
ياردة
كلا
السنة
2006
المصنّع
الطراز
نوع الأصل
الرقم التسلسلي أو رقم تعريف المركبة
225919
الميزات
Air Conditioner, Eaton Fuller 9LL Manual Transmission, 20780 hrs Carrier Engine, Cummins 6 Cylinder Diesel Carrier Engine, Air Conditioner, Anti Two-Block, PAT Load Moment Indicator, 36 ft Minimum 110 ft Maximum Boom Length, Auxiliary Hoist, Rooster Sheave, 33 ft to 56 ft Bifold Swingaway Offset Jib, 40 ton Capacity Johnson 3 Sheave Hook Block, Overhaul Ball, Counterweight Removal System
ملحوظات
COMES WITH IRONCLAD ASSURANCE. SUBJECT TO TEXAS SALES TAX.
Picture, Left Front Corner
Picture, Left Rear Corner
Picture, Right Rear Corner
Picture, Right Front Corner
Serial Number / VIN
225919
Hour Meter / Odometer
167773 mi-No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Paint
Sheet Metal (fiberglass) Condition
Steps/Ladders
Hand Rails
Glass
Exterior Lights
Operational
Safety Certification Label
There was no safety certification label located on the machine.
Safety Certification Report
Safety Certification Report Not Available
Load Chart
Yes
Travel Alarm
Operational
Horn
Operational
Seat Belts
Operational
Safety Lock Out/Stop
Operational
Current Safety Manual
Current Operator/Maintenance Manual
Lower/Carrier Engine Hours
20780 hrs Carrier Engine
Mirrors
Window Controls
Operational Difficult to roll up
Seats/armrests
Seat Belts
Operational
Steering Control
Horn
Operational, Operational
Engine Oil Pressure
Gauge inoperable
Warning Lights
Operational
Gauges
Fuel, temperature, oil pressure and voltage. gauges are inoperable
Gear Selector
Brake Control
Engine Brake
Not operationally checked
Clutch
Engages
PTO Control
Electric engaged, Operational
ECM Miles
162491 mi
Air Conditioner
Inoperable
Heater
Not operationally checked
Limited Function Check
The main components are in place and operational as noted.
A/C Compressor
Compressor will not engage
Blow-by (subjective visual observation)
Minor
Starter
Operational
Air Compressor
Operational
Fuel System
Operational
Exhaust System
Radiator
Oil Leaks
No dripping leaks
Fuel Leaks
No dripping leaks
Cooling System Leaks
No dripping leaks
Engine - Left Side
Engine - Right Side
Limited Function Check
The engine started and ran.
Transmission
Operational
Clutch
Engages
Steer Axle
Front Drive Axle
Rear Drive Axle
Axle Bump Stops
In place
Final Drives
Limited Function Check - Carrier
The drivetrain was operational without a load.
Steering Linkage
Steering Wheel Play
Brake Type
Air
Master Cylinder/Brake Control
Brake Lines/Hoses
Park Brake
Limited Function Check - Brakes
The brake system functioned, stopping and holding the machine.
Springs/Hangers Condition
Suspension Air Bags
Frame Condition
Tire Condition
Wheel Condition
Wheel Studs
Pumps (Hydraulics)
Seepage
Valves
Hydraulic Tank
Hoses (Hydraulic)
Stabilizer Cylinders
Limited Function Check
The hydraulic system was operational. Seepage at oil cooler.
Hour Meter Reading
22 Hours, Meter inoperable-IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Glass
Seats/Armrests
Safety Lock Out/Stop
Load Moment Indicator
Operational, Not operationally checked with a load
Anti Two Block
Operational
Hydraulic Controls
Exterior Lights
Warning Lights
Operational
Gauges
Operational, Most gauges are missing
Drum Rotation Indicator
Operational, Auxiliary drum indicator is damaged.
Air Conditioner
Inoperable
Heater
Not operationally checked
Limited Function Check
The main components are in place and operational as noted.
Main Boom Pins
Main Boom Sections
Sheaves
Boom Head Section
Wear Pads
Turntable Bearing
Limited Function Check
The main crane components functioned when checked without a load.
Outrigger Beams
Outrigger Cylinders
Outrigger Pads
Bent
Hydraulic Motors
Hoses (Hydraulic)
Swing Motor
Main Hoist
Auxiliary Hoist
Lift Cylinders
Dripping leak
Telescopic Boom Cylinders
Jib
Main Load Block
Overhaul Ball
Counterweights
يجب دفع المبلغ الكامل للعناصر بحلول الثلاثاء، 14 أكتوبر 2025. ستُطبق رسوم تأخير بعد تاريخ الاستحقاق.
المدفوعاتالمعلومات التفصيلية حول المعدات محدودة النطاق، ولم تفحص شركة ريتشي وإخوانه للمزادات العلنية أي جوانب أو مكونات من المعدات بخلاف تلك المنصوص عليها صراحة في هذه الوثيقة. ما لم يُنص صراحة على ذلك، نحن لا نقدم أي تعهدات أو ضمانات، صريحة أو ضمنية، في ما يتعلق بالمعدات أو مكوناتها، بما في ذلك على سبيل المثال لا الحصر أي تعهدات أو ضمانات تتعلق بالتشغيل أو المطابقة أو الامتثال لأي معيار أمان أو متطلبات أي سلطة أو هيئة تنظيمية معنية، أو الملاءمة لأي غرض معين، أو قابلية التسويق. ننصحك بشدة بإجراء فحص تفصيلي خاص بك للمعدات قبل تقديم المزايدات.
لم تُختبر المعدات تحت حمل ولم تُشغَّل على جميع السرعات المتاحة. نحن لا نقدم أي تعهد أو ضمان بأن المعدات تعمل وفق مواصفات الشركات المصنعة. لم يُجرَ أي فحص في ما يتعلق بأي جانب تشغيلي بخلاف تلك الجوانب المدرجة صراحة في هذه الوثيقة. تم توفير صور مختارة لبعض مكونات الهيكل السفلي الفردية، وقد لا تعكس هذه الصور حالة الهيكل السفلي بأكمله.
القياسات مُقدمة بشكل تقريبي فقط. قد تختلف الأبعاد الفعلية للحمولة بناءً على ارتفاع الشاحنة/المقطورة وتكوين/وضع الآلة المُحمَّلة. تقع على عاتق المشتري مسؤولية قياس جميع الأحمال قبل مغادرة موقع المزاد الخاص بنا لضمان أن الحمولة آمنة للنقل. يجب أن يتحقق المشتري من جميع القياسات. لا تعتمد على هذه القياسات لأغراض النقل.