98 من الصور
الموقع
Baltimore, MD
Baltimore, MD
الاستخدام
27,080 ساعات
27,080 ساعات
الرقم التسلسلي
WLHZ0194CZK030324
WLHZ0194CZK030324
Loading...
هذه المجموعة محمية بموجب IronClad Assurance
اشترِ بثقة عندما تعرف أنَّ هذه المجموعة قد فُحصت تفصيليًا وبالكامل بواسطة فاحِص مؤهل.
رقم الهوية
#14919110
ياردة
كلا
الميزات
Air Conditioner, Hydraulic Cab Riser, Surround View Cameras, 2006 US EPA Label, Auxiliary Hydraulic Plumbing, Front and Rear Stabilizers, 20.5x25 Tires, Manual Quick Coupler




















Serial Number / VIN
WLHZ0194CZK030324
Hour Meter / Odometer
27080 hrs-No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Paint
Sheet Metal (fiberglass) Condition
Steps/Ladders
Hand Rails
Glass
The windshield is cracked.
Exterior Lights
Some not operational, Right boom light lights are not operational

Travel Alarm
Inoperable
Horn
Missing
Seat Belts
Operational
Safety Lock Out/Stop
Operational
Swing Brake
Operational
Current Safety Manual
Current Operator/Maintenance Manual














Seats/Armrests
Steering Control
Hydraulic Controls
Drivetrain Controls
Oil Pressure
The fault indicator shuts off after the engine oil pressure rises.
Warning Lights
Operational
Gauges
Operational
Air Conditioner
The ambient temperature is too cold to check.
Heater
Operational
Limited Function Check
The main components are in place and operational as noted.















Engine
2006 US EPA Label
Emission Label
A/C Compressor
In place; ambient temperature too cold to check operation
Blow-by (subjective visual observation)
Minor
Starter
Operational
Exhaust System
Radiator
Oil Leaks
Side of engine, Oil Pan, Valve cover
Fuel Leaks
No dripping leaks
Cooling System Leaks
No dripping leaks
Engine - Left Side
Engine - Right Side
Limited Function Check
The engine started and ran.










Drive Motors
Front Drive Axle
Front Axle Oscillating Pin
Rear Drive Axle
Final Drives
Limited Function Check
The drivetrain was operational.




















Pumps (Hydraulics)
Dripping leak
Valves
Dripping leak
Hydraulic Tank
Sight glass leak
Hoses (Hydraulics)
Auxiliary Hydraulic Plumbing
Operational, End of stick
Swing Motor
Hydraulic Center Swivel
Boom Lift Cylinder(s)
Stick Cylinder
Limited Function Check
The hydraulic system was operational.

















Boom Condition
Stick Condition
Boom Base Pin and Bushings
Pin and Bushings Boom to Stick
Pins and Bushings Stick to Coupler
Turntable Bearing
Bottom Covers
Stabilizers
Operational
Limited Function Check
The main components were operational in a limited check.
Steering Linkage
Frame Condition
Limited Function Check
The main chassis components functioned during a limited check.
Brake Control
Park Brake
Limited Function Check - Brakes
The brake system functioned, stopping and holding the machine.
Left Front Tire
Left Rear Tire
Right Rear Tire
Right Front Tire
Wheel Condition
Wheel Studs, Nuts, Lugs

Quick Coupler
Not operationally checked
Oil Sample Analysis
| engine | |
|---|---|
| date of analysis | Mar 30, 2026 |
| Silicon | 2.99 PPM |
| Tin | 0 PPM |
| Silver | 0 PPM |
| Aluminum | 0.98 PPM |
| Chromium | 0 PPM |
| Lead | 1.41 PPM |
| Copper | 1.82 PPM |
| Nickel | 0.13 PPM |
| Iron | 41.59 PPM |
| Glycol | NEG |
| Water | NEG |
| Fuel | <5% |
يجب دفع المبلغ الكامل للعناصر بحلول الأربعاء، 8 يناير 3000. ستُطبق رسوم تأخير بعد تاريخ الاستحقاق.
انقل معداتك حيث يجب أن تكون مع حلول الشحن واللوجستيات المتكاملة من الباب إلى الباب من ريتشي وإخوانه. نهتم بكل خطوة في الرحلة من خلال خدمتنا الشاملة لعبور معداتك للحدود والقارات والمحيطات بسرعة وكفاءة
المعلومات التفصيلية حول المعدات محدودة النطاق، ولم تفحص شركة ريتشي وإخوانه للمزادات العلنية أي جوانب أو مكونات من المعدات بخلاف تلك المنصوص عليها صراحة في هذه الوثيقة. ما لم يُنص صراحة على ذلك، نحن لا نقدم أي تعهدات أو ضمانات، صريحة أو ضمنية، في ما يتعلق بالمعدات أو مكوناتها، بما في ذلك على سبيل المثال لا الحصر أي تعهدات أو ضمانات تتعلق بالتشغيل أو المطابقة أو الامتثال لأي معيار أمان أو متطلبات أي سلطة أو هيئة تنظيمية معنية، أو الملاءمة لأي غرض معين، أو قابلية التسويق. ننصحك بشدة بإجراء فحص تفصيلي خاص بك للمعدات قبل تقديم المزايدات.
لم تُختبر المعدات تحت حمل ولم تُشغَّل على جميع السرعات المتاحة. نحن لا نقدم أي تعهد أو ضمان بأن المعدات تعمل وفق مواصفات الشركات المصنعة. لم يُجرَ أي فحص في ما يتعلق بأي جانب تشغيلي بخلاف تلك الجوانب المدرجة صراحة في هذه الوثيقة. تم توفير صور مختارة لبعض مكونات الهيكل السفلي الفردية، وقد لا تعكس هذه الصور حالة الهيكل السفلي بأكمله.
القياسات مُقدمة بشكل تقريبي فقط. قد تختلف الأبعاد الفعلية للحمولة بناءً على ارتفاع الشاحنة/المقطورة وتكوين/وضع الآلة المُحمَّلة. تقع على عاتق المشتري مسؤولية قياس جميع الأحمال قبل مغادرة موقع المزاد الخاص بنا لضمان أن الحمولة آمنة للنقل. يجب أن يتحقق المشتري من جميع القياسات. لا تعتمد على هذه القياسات لأغراض النقل.