E9J02315
E9J02315
Loading...
هذه المجموعة محمية بموجب IronClad Assurance
اشترِ بثقة عندما تعرف أنَّ هذه المجموعة قد فُحصت تفصيليًا وبالكامل بواسطة فاحِص مؤهل.
رقم الهوية
#15443629
ياردة
كلا
الميزات
Eaton Fuller 8LL Manual Transmission, 14754 hrs Carrier Engine, 1999 US EPA Label, Detroit Series 60 6 Cylinder 11.1 L Diesel Carrier Engine, Anti Two-Block, Microguard 434 Load Moment Indicator, 35 ft Minimum 110 ft Maximum Boom Length, Auxiliary Hoist, 34 ft to 56 ft Bifold Swingaway Jib, 1030 lb 50 lb Capacity Johnson 3 Sheave Hook Block, 375 lb 8.5 ton Capacity Overhaul Ball, 12000 lb Counterweight, Counterweight Removal System
ملحوظات
<br><br>**No title is available. A Bill of Sale will be provided to convey ownership upon request**

















Serial Number / VIN
E9J02315
Hour Meter / Odometer
91890 mi-No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Paint
Sheet Metal (fiberglass) Condition
Steps/Ladders
Hand Rails
Glass
Exterior Lights
Some not operational
Safety Certification Label
There is a safety certification label with a date of 2026
Safety Certification Report
Safety Certification Report Available
Load Chart
Yes

Travel Alarm
Operational
Horn
Operational
Seat Belts
Operational
Current Safety Manual
Current Operator/Maintenance Manual



















Lower/Carrier Engine Hours
14754 hrs Carrier Engine
Mirrors
Window Controls
Operational
Seats/armrests
Seat Belts
Operational
Steering Control
Horn
Operational
Engine Oil Pressure
The gauge registers in the operating range.
Warning Lights
Operational
Gauges
Operational
Gear Selector
Brake Control
Clutch
Engages
PTO Control
Air engaged, Operational
ECM Miles
Unable to get ECM reading
Heater
Not operationally checked
Limited Function Check
The main components are in place and operational as noted.














Emissions Status
Other 1999 US EPA Label
Emission Label
Blow-by (subjective visual observation)
No noticeable vapor or pressure
Starter
Operational
Air Compressor
Operational
Fuel System
Operational
Exhaust System
Radiator
Oil Leaks
No dripping leaks
Fuel Leaks
No dripping leaks
Cooling System Leaks
No dripping leaks
Engine - Left Side
Engine - Right Side
Limited Function Check
The engine started and ran.



















Transmission
Operational
Clutch
Engages
PTO Pump
Steer Axle
Front Drive Axle
Rear Drive Axle
Axle Bump Stops
Limited Function Check - Carrier
The drivetrain was operational without a load.
Steering Linkage
Steering Wheel Play
Brake Type
Air
Master Cylinder/Brake Control
Brake Lines/Hoses
Park Brake
Stopped the machine while rolling
Limited Function Check - Brakes
The brake system functioned, stopping and holding the machine.
Springs/Hangers Condition
Suspension Air Bags
Frame Condition
Cross Members
Tire Condition
Wheel Condition
Wheel Studs









Pumps (Hydraulics)
Valves
Hydraulic Tank
Hoses (Hydraulic)
Stabilizer Cylinders
Limited Function Check
The hydraulic system was operational.




















Mirrors
No visible damage or missing components
Glass
Seats/Armrests
Load Moment Indicator
Operational
Anti Two Block
Operational
Hydraulic Controls
Oil Pressure
The gauge registers in the operating range.
Exterior Lights
Gauges
Operational
Hoist Brakes
Drum Rotation Indicator
Heater
Not operationally checked
Limited Function Check
The main components are in place and operational as noted.






















Main Boom Pins
Main Boom Sections
Sheaves
Boom Head Section
Wear Pads
Boom Angle Indicator
In the Load Moment Indicator
Turntable Bearing
Limited Function Check
The main crane components functioned when checked without a load.
Outrigger Beams
Outrigger Cylinders
Outrigger Pads














Pumps (Hydraulics)
Hydraulic Motors
Valves
Hydraulic Tank
Hoses (Hydraulic)
Swing Motor
Main Hoist
Auxiliary Hoist
Lift Cylinders
Telescopic Boom Cylinders








Jib
Main Load Block
Overhaul Ball
Counterweights
Oil Sample Analysis
| engine | |
|---|---|
| date of analysis | Jul 16, 2026 |
| Silicon | 0 PPM |
| Tin | 1.67 PPM |
| Silver | 0 PPM |
| Aluminum | 0 PPM |
| Chromium | 0.49 PPM |
| Lead | 5.52 PPM |
| Copper | 2.32 PPM |
| Nickel | 0.05 PPM |
| Iron | 12.62 PPM |
| Glycol | NEG |
| Water | NEG |
| Fuel | <5% |
يجب دفع المبلغ الكامل للعناصر بحلول الأربعاء، 8 يناير 3000. ستُطبق رسوم تأخير بعد تاريخ الاستحقاق.
انقل معداتك حيث يجب أن تكون مع حلول الشحن واللوجستيات المتكاملة من الباب إلى الباب من ريتشي وإخوانه. نهتم بكل خطوة في الرحلة من خلال خدمتنا الشاملة لعبور معداتك للحدود والقارات والمحيطات بسرعة وكفاءة
المعلومات التفصيلية حول المعدات محدودة النطاق، ولم تفحص شركة ريتشي وإخوانه للمزادات العلنية أي جوانب أو مكونات من المعدات بخلاف تلك المنصوص عليها صراحة في هذه الوثيقة. ما لم يُنص صراحة على ذلك، نحن لا نقدم أي تعهدات أو ضمانات، صريحة أو ضمنية، في ما يتعلق بالمعدات أو مكوناتها، بما في ذلك على سبيل المثال لا الحصر أي تعهدات أو ضمانات تتعلق بالتشغيل أو المطابقة أو الامتثال لأي معيار أمان أو متطلبات أي سلطة أو هيئة تنظيمية معنية، أو الملاءمة لأي غرض معين، أو قابلية التسويق. ننصحك بشدة بإجراء فحص تفصيلي خاص بك للمعدات قبل تقديم المزايدات.
لم تُختبر المعدات تحت حمل ولم تُشغَّل على جميع السرعات المتاحة. نحن لا نقدم أي تعهد أو ضمان بأن المعدات تعمل وفق مواصفات الشركات المصنعة. لم يُجرَ أي فحص في ما يتعلق بأي جانب تشغيلي بخلاف تلك الجوانب المدرجة صراحة في هذه الوثيقة. تم توفير صور مختارة لبعض مكونات الهيكل السفلي الفردية، وقد لا تعكس هذه الصور حالة الهيكل السفلي بأكمله.
القياسات مُقدمة بشكل تقريبي فقط. قد تختلف الأبعاد الفعلية للحمولة بناءً على ارتفاع الشاحنة/المقطورة وتكوين/وضع الآلة المُحمَّلة. تقع على عاتق المشتري مسؤولية قياس جميع الأحمال قبل مغادرة موقع المزاد الخاص بنا لضمان أن الحمولة آمنة للنقل. يجب أن يتحقق المشتري من جميع القياسات. لا تعتمد على هذه القياسات لأغراض النقل.